MODEL |
SU-103s |
SU-103sr |
SU-103F |
Input sensor |
Thermistor |
Thermistor |
Thermistor |
Measure range |
-40.0~99.9 |
-40.0~99.9 |
-40.0~99.9 |
SENSOR |
Attach |
Attach |
Attach |
Precision |
F.S 0.3% |
F.S 0.3% |
F.S 0.3% |
Indication unit
|
0.1 ± 1DIGIT 1 ± 1DIGIT |
Source of electricity
- Basic form : AC100~240V(change rate of permission power ± 10%)
- Option : DC12V, DC24V
OUT1
- Basic form : Relay output(AC250/5A, DC12V, A, B contact), Conversion of Cooling control(C), Heating control(H),Possibility of conversion into ON/OFF control and proportional control (defrosting timer)
- Option : SSR out(DC12V)
OUT2
- Basic form : Relay output(AC250/2A, DC12V, A, B contact), Conversion of Cooling control(C), Heating control(H),
Possibility of conversion into ON/OFF control and proportional control (defrosting timer)
possibility of separated setting from OUT1 (example) SV1:25.0 SV2:50.0 OUT1: cooling, OUT2 : heating (SU-103s has no OUT2)
- Option : SSR output(DC12V)
OUT3
- Cooling Fan Function(SU-103s,SU-103sr has no OUT3)
Relay Durability
- Mechanical load : about one million times and above
- electrical durability : three hundred thousand times and above
Special feature
- Filtering :Provide Clear Indication Screen long lasting
- Assurance of input sensor : Compensate the Temperature Difference coming from Wire Length or Old Equipment, etc.
- Limit of setting range
- Measuring Range Setting Available & Lock System Available for Security
- Change OUT2 to On/Off Timer, Available
- COMP and Frost Removal Function: With or Separately Operation Setting Available
- The Frost Removal Risk Temperture Setting function: Available
SIZE
- Dimensions : (W) 76mm× (H) 34mm
- Panel size : (W) 0mm× (H) 28mm